Browsing by Author "Fazlul Rahman Mohd Yunus"
Now showing 1 - 3 of 3
Results Per Page
Sort Options
- Some of the metrics are blocked by yourconsent settings
Publication A Review of Tomography System(Penerbit Universiti Teknologi Malaysia (Penerbit UTM Press), 2013) ;Juliza Jamaludin ;Mohd Zikrillah Zawahir ;Ruzairi Abdul Rahim ;Fazlul Rahman Mohd Yunus ;Nor Muzakkir Nor Ayob ;Muhammad, Suzzana Ridzuan Aw ;Naizatul Shima Fadzil ;Zulkarnay ZakariaMohd Hafiz Fazalul RahimanTomography system is a method that being used to reconstruct a cross sectional image in vessel or pipeline. This method is widely used in medical and industrial fields. The aim of this paper is to provide an overview of tomography system based on its basics construction, types of sensors, its applications in today’s industry, and image reconstruction. This paper review consists of literature citations which related with tomography system. - Some of the metrics are blocked by yourconsent settings
Publication Simulation Study on Electrical Resistance Tomography using Metal Wall for Bubble Detection(Penerbit UTM Press, 2015) ;Suzanna Ridzuan Aw ;Ruzairi Abdul Rahim ;Mohd Hafiz Fazalul Rahiman ;Elmy Johana Mohamad ;Fazlul Rahman Mohd Yunus ;Yasmin Abdul Wahab ;Naizatul Shima FadzilJuliza JamaludinIndustrial process pipelines are mostly known to be constructed from metal which is a conducting material. Bubbles or gas detection are crucial in facilitating the bubble columns performance. By employing the Electrical Resistance Tomography (ERT) technique, a simulation study using COMSOL has been conducted to investigate the effect of excitation strategy, bubble sizes and locations towards the metal wall system. As for the current excitation strategy, conducting boundary protocol has to be applied when it comes to metallic vessel to overcome the grounding effect. Bubbles with a greater size than 2 mm and especially the one that is located near the wall boundary are much easier to detect. Further potential improvements to the current design and image reconstruction of the ERT system are desirable to improve the detection of small and centred bubble. - Some of the metrics are blocked by yourconsent settings
Publication Simulation Study On Non-Homogenous System Of Non-Invasive ERT Using Comsol Multiphysics(Penerbit UTM Press, 2015) ;Yasmin Abdul Wahab ;Ruzairi Abdul Rahim ;Mohd Hafiz Fazalul Rahiman ;Leow Pei Ling ;Suzzana Ridzuan Aw ;Fazlul Rahman Mohd Yunus ;Herlina Abdul Rahim ;Naizatul Shima Fadzil ;Mohd Zikrillah Zawahir ;Juliza Jamaludin ;Muhammad Saiful Badri Mansor ;Mohd Fadzli Abdul SahibLing En HongThe non-invasive sensing technique is one of the favourite sensing techniques applied in the process tomography because it has not a direct contact with the medium of interest. The objective of this paper is to analyse the simulation of the non-homogenous system of the non-invasive ERT using finite element software; COMSOL Multiphysics. In this simulation, the liquid-air medium is chosen as the non-homogenous system. A different analysis of the non-homogenous system in term of the different position of the single air, different size of the single air and the multiple air inside the vessel were investigated in this paper. As a result, the location, size and multiple air inside the pipe will influence the output of the non-invasive ERT system. A liquid-gas medium of non-homogenous ERT system will have a good response if the air is located near the source, the size of the air is large enough and it has multiple air locations inside the pipe.