Browsing by Author "Rahim, RA"
Now showing 1 - 13 of 13
Results Per Page
Sort Options
- Some of the metrics are blocked by yourconsent settings
Publication Analysis on the Effect of Sensor Views in Image Reconstruction Produced by Optical Tomography System Using Charge-Coupled Device(IEEE-INST Electrical Electronics Engineers Inc, 2018) ;Jamaludin J. ;Rahim, RA ;Rahiman, MHFRohani, JMOptical tomography (OPT) is a method to capture a cross-sectional image based on the data obtained by sensors, distributed around the periphery of the analyzed system. This system is based on the measurement of the final light attenuation or absorption of radiation after crossing the measured objects. The number of sensor views will affect the results of image reconstruction, where the high number of sensor views per projection will give a high image quality. This research presents an application of charge-coupled device linear sensor and laser diode in an OPT system. Experiments in detecting solid and transparent objects in crystal clear water were conducted. Two numbers of sensors views, 160 and 320 views are evaluated in this research in reconstructing the images. The image reconstruction algorithms used were filtered images of linear back projection algorithms. Analysis on comparing the simulation and experiments image results shows that, with 320 image views giving less area error than 160 views. This suggests that high image view resulted in the high resolution of image reconstruction. - Some of the metrics are blocked by yourconsent settings
Publication Analysis On The Performance Of Led And Laser Diode With Charge Coupled Device (CCD) Linear Sensor Measuring Diameter Of Object(Penerbit UTM Press, 2015) ;Jamaludin J. ;Rahim, RA ;Rahim, HA ;Rahiman, HF ;Muji, SZM ;Jumaah, MF ;Fadzil, NSM ;Ahmad, N ;Sahlan, S ;Ahmad, A ;Yunus, YAbas, KHSimple experiment measuring diameter of a solid object (coin) using LED and laser diode with Charge Coupled Device (CCD) linear sensor was conducted in this early stage study. Mostly, CCD and laser diode system are higher in cost because CCD used in industries equipped with an anti blooming protection system to protect the CCD pixel from receiving too high laser light intensities. Low cost atomic laser (Helium: Neon 10: 1) with simple modification on light propagation is introduced. Combination of fan beam and parallel beam projection helps to reduce light intensities and expand laser light coverage area. Statistical analyses based on dot plot graph, Anderson Darling test and T-test were applied to choose the best transmitter for Charge Coupled Device (CCD) sensor. Based on T-test results with 95% confidence interval, low intensity laser diode for 5 and 10 cent diameter measurement gave P-value greater than 0.05, accepts laser as the best transmitter compared to LED. Single sensor data for LED and laser used for image reconstruction as an additional approach to prove the above result. - Some of the metrics are blocked by yourconsent settings
Publication CCD Optical Tomography System to Detect Solid Contamination in Crystal-Clear Water(IEEE-Inst Electrical Electronics Engineers Inc, 2020) ;Jamaludin J. ;Rahim, RA ;Rahiman, MHFRohani, JMThe existence of foreign objects in crystal-clear water in beverage industries may cause major safety and health issues. The current observation of solid contamination such as X-ray and metal detector involves hazardous radiation. Some of the sensors applied intrusive and invasive techniques. This may cause the instability of the process flow. Therefore, this paper aims to develop a noninvasive and nonintrusive charge-coupled device optical tomography (CCD OPT) system to detect solid contamination in crystal-clear water. Investigations on three different opacity levels of objects, opaque, translucent, and transparent, are involved. The first experiment investigates the velocity and acceleration of the free-falling object. It is conducted to validate the accuracy of the system to detect the appearance of foreign object. The experiment result indicated that the system reached 82 accuracy. The second experiment reconstructs cross-sectional image of the process flow. The image reconstruction results are analyzed using the area error (AE) method. The image reconstruction AE range is between 0.0372 and 0.7269. The AE results show that the system has the capability to detect different opacity of objects which exist in crystal-clear water. Both experiments prove that the CCD OPT system is able to detect solid contamination in crystal-clear water. - Some of the metrics are blocked by yourconsent settings
Publication Charge coupled device based on optical tomography system in detecting air bubbles in crystal clear water(Elsevier Sci Ltd, 2016) ;Juliza Jamaludin ;Rahim, RA ;Rahim, HA ;Rahiman, MHF ;Muji, SZMRohani, JMOptical tomography is one of the tomography methods which are non-invasive and non-intrusive system, consisting of emitter with detectors. Most of the available detectors systems are intrusive where sensors or probes need to be placed within the analyzed processes and this will create disturbances in the current processes. This research are conducted in order to analyze and proved the capability of laser with Charge Coupled Device in an optical tomography system for detecting air bubbles exist in crystal clear water. Experiments in detecting moving air bubbles are conducted. The images of captured data are reconstructed based on filtered image of Linear Back Projection with Hybrid algorithms. As a conclusion, this research have successfully developed an optical tomography system that capable to capture the image and measure the diameter and velocity of rising air bubbles in a non-flowing crystal clear water. (C) 2016 Elsevier Ltd. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Publication Charge-Coupled Device Based on Optical Tomography System for monitoring multiphase flow(Univ Tun Hussein Onn Malaysia, 2017) ;Jamaludin J. ;Rahim, RA ;Rahiman, MHF ;Muji, SZM ;Rohani, JMWahab, YATomography is a method to capture a cross-sectional image based on the data obtained by sensors, distributed around the periphery of the analyzed system. Optical tomography is one of the tomography methods which are non-invasive and non-intrusive system, consisting of emitter with detectors. Combinations of Charge-Coupled Device and low intensity laser diode are used in this research. Experiments on air bubbles detecting in non-flowing crystal clear water are conducted. Cross-sectional image of two phase flow; air and liquid are captured using this optical hardware construction and the information on air diameter, shape and path are observed using LabVIEW programming. - Some of the metrics are blocked by yourconsent settings
Publication Charge-coupled device based on optical tomography system for monitoring two-phase flow(Inst Engineering Technology-Iet, 2017) ;Jamaludin J. ;Rahim, RA ;Rahim, HA ;Rahiman, MHFRohani, JMAn application of charge-coupled device (CCD) linear sensor and laser diode in an optical tomography (OPT) system is presented. The measurements are based on the final light intensity received by the sensor. The aim is to analyse and demonstrate the capability of laser with a CCD in an OPT system for detecting transparent objects in crystal clear water. The image reconstruction algorithms used were filtered images of linear back projection algorithms. These algorithms were programmed using LabVIEW programming software. Experiments in detecting transparent hollow straw were conducted. Based on the results, statistical analysis was performed to verify that the captured data were valid compared with the actual object data. The object's characteristics such as diameter also are observed. In conclusion, a non-intrusive and non-invasive OPT system that can detect transparent objects in crystal clear water is successfully developed. - Some of the metrics are blocked by yourconsent settings
Publication Charge-coupled device based on optical tomography system in detecting solid and transparent objects in non-flowing crystal clear water(ELSEVIER GMBH, URBAN & FISCHER VERLAG, 2017) ;Jamaludin J. ;Rahim, RA ;Rahim, HBA ;Rahiman, MHF ;Rohani, JMMuji, SZBMTomography is a method to capture a cross-sectional image based on the data obtained by sensors, distributed around the periphery of the analyzed system. Optical tomography is one of the tomography methods which are non-invasive and non-intrusive System, consisting of emitter with detectors. Most of the available detectors systems are intrusive where sensors or probes need to be placed within the analyzed processes and this Will create disturbances in the current processes. This research are conducted in order to analyze and proved the capability of laser with Charge Coupled Device in an optical tomography system for detecting difference type of opacity object exist in crystal clear water. Experiments in detecting static solid, transparent objects and moving air bubbles are conducted. The images of captured data are reconstructed based on filtered image of Linear Back Projection with Hybrid algorithms. As a conclusion, this research have successfully developed an optical tomography system that capable to capture the image of high to low opacity objects in a non-flowing crystal clear water. (C) 2016 Elsevier GmbH. All rights reserved. - Some of the metrics are blocked by yourconsent settings
Publication Introducing an Application of a Charged Coupled Device (CCD) in an Optical Tomography System(Penerbit UTM Press, 2015) ;Jamaludin J. ;Rahim, RA ;Rahim, HA ;Rahiman, HF ;Muji, SZM ;Fadzil, NSM ;Ling, LP ;Jumaah, F ;Ahmad, A ;Ayob, NMNHong, LEA tomographic system is a method used for capturing an image of an internal object section. Optical tomography is one method which widely used in medical and industrial fields. This paper reviews several applications of Charged Coupled Devices (CCD) and introduces an application of a CCD in an optical tomography system. Most of the previous research used this component for displacement measurement and as a video camera. This paper discusses its basic principle of operation, basic construction, its criteria, application, and its advantages compared to other optoelectronic sensors available in today's market. The applications of this sensor in fields such as astronomy and medical has proved the ability and the good performance of CCD in capturing images. This sensor should widen its usage in optical tomography fields because it can give high performance in image reconstruction. - Some of the metrics are blocked by yourconsent settings
Publication Microwave tomography sensing for potential agarwood trees imaging(Elsevier Sci Ltd, 2019) ;Rahiman, MHF ;Thomas, TWK ;Soh, PJ ;Rahim, RA ;Jamaludin J. ;Ramli, MFZakaria, ZAgarwood or its scientific name, Aquilaria is an expensive and precious non-timber forest product. The problems faced by the agarwood industry are the indiscriminate harvesting of agarwood and ineffective identification and inspection process of Aquilaria tree by agarwood prospectors and researchers. Hence, microwave tomography (MWT) is proposed to evaluate agarwood in order to encounter these problems. This technique operates in a safe, non-invasive and insensitive to environmental impacts. A simulation-based study had been performed in which 16 antennas microwave tomography system was modelled using the finite element analysis. In this study, six profiles were being tested and simulated at 1 GHz. An electric field was simulated based on transverse electric mode to be emitted into the modelled wood with agarwood. Besides, electric field at the receiving antennas was also simulated when the simulated incident field was emitted into the modelled wood. The readings of the electric field for both incidents and receiving antennas were recorded to find the difference of electric field which will be used for image reconstruction. The images for the six profiles were reconstructed using Linear Back Projection (LBP), Filtered Back Projection (FBP), Newton's One-Step Error Reconstruction (NOSER) and Tikhonov Regularization (TR) image reconstruction algorithms. The reconstructed images were then analysed using the Mean Structural Similarity (MSSIM) index. The phantom and reconstructed images were analysed qualitatively and quantitatively. The findings showed promising results as the proposed MWT was able to distinguish and identify agarwood in Aquilaria tree. - Some of the metrics are blocked by yourconsent settings
Publication Online Optical Tomography System for Detecting and Measuring the Diameters of Solid and Transparent Objects(IEEE-Inst Electrical Electronics Engineers Inc, 2016) ;Jamaludin J.Rahim, RAThis paper presents an application of a charge coupled device (CCD) linear sensor and laser diode in an optical tomography (OPT) system. OPT is a non-invasive and non-intrusive tomography system consisting of an emitter with detectors. This paper is conducted in order to analyze and prove the capability of a laser with a CCD in an OPT system for detecting and measuring the diameter of an object that exists in crystal clear water. Experiments in detecting and capturing static solid and transparent objects are conducted using this hardware and software development. Statistical engineering methods were applied to analyze and validate the experimental data. Investigations of the effect of number of sensor views and object opacity level were also carried out in this paper. In conclusion, this paper has successfully developed an OPT system that is capable of detecting the appearance and measuring the diameter of objects with different opacity levels in non-flowing crystal clear water. - Some of the metrics are blocked by yourconsent settings
Publication Optical Tomography System Using Charge-Coupled Device for Transparent Object Detection(Univ Tun Hussein Onn Malaysia, 2018) ;Jamaludin J. ;Rahim, RA ;Rahiman, MHF ;Wahab, YA ;Rohani, JM ;Sahrim, M ;Wan Zakiah Wan Ismail ;Irneza IsmailBalakrishnan, SRThis research presents an application of Charge-Coupled Device (CCD) linear sensor and laser diode in an optical tomography system. Optical tomography is a non-invasive and non-intrusive method of capturing a cross-sectional image of multiphase flow. The measurements are based on the final light intensity received by the sensor and this approach is limited to detect solid objects only. The aim of this research is to analyse and demonstrate the capability of laser with a CCD in an optical tomography system for detecting objects with different clarity in crystal clear water. Experiments for detecting transparent objects were conducted. The object's diameter and image reconstruction can also be observed. As a conclusion, this research has successfully developed a non-intrusive and non-invasive optical tomography system that can detect objects in crystal clear water. - Some of the metrics are blocked by yourconsent settings
Publication Optical tomography system: Application of Charge Coupled Device (CCD) for solid and transparent objects detection(Penerbit UTM Press, 2016) ;Jamaludin J. ;Rahim, RA ;Rahim, HA ;Rahiman, HF ;Muji, SZM ;Jumaah, MF ;Fadzil, NSM ;San, CKGreen, RGThis research presents an application of Charge Coupled Device (CCD) linear sensor and laser diode in an optical tomography system. These optoelectronic sensors are believed to detect solid objects rather than transparent objects. Based on the research results, the development of optical tomography system using Charge Coupled Device (CCD) and laser diode has helped to enhance the potential of these sensors in detecting high to low opacity objects. Experiments for detecting a solid rod, glass rod and transparent hollow straw in non-flowing crystal clear water were conducted in this study. Investigation on the effect of number of views also studied in this research. From the image reconstruction results, it clearly shows a cross-sectional image of a pipeline system with the existence of opaque and transparent objects in multiphase flows. For 320 views image reconstruction, it gives high resolution of image results compared to 160 views image reconstruction. - Some of the metrics are blocked by yourconsent settings
Publication A Review of the Optical Tomography System(Penerbit Utm Press, 2014) ;Jamaludin J. ;Rahim, RA ;Rahim, HA ;Fadzil, NSM ;Rahiman, MHF ;Jumaah, MF ;Muji, SZMYunus, MAMTomography is a method that has been used for image reconstruction in the medical and engineering fields. Optical tomography is one of the various methods applied in tomography systems. This tomography method is widely used in the medical and processing industries fields because of its special characteristics, such as immunity to electrical noise and interference, high resolution and its hard field sensors. The basic principle of the optical tomography system in measuring an object is based on its wave and radiation source. This article is a review of the characteristics of light and its interaction with matter, the types of optical tomography system, the basic construction of an optical tomography system, types of optoelectronic sensors and image reconstruction.