Publication:
The Optimum Duration of Flushing Dental Unit Waterlines for Microbial Removal

dc.contributor.authorJohn Chong Keat Honen_US
dc.contributor.authorSiti Noor Adnalizawati Adnanen_US
dc.contributor.authorNur Aqilah Ismailen_US
dc.date.accessioned2024-05-28T06:40:16Z
dc.date.available2024-05-28T06:40:16Z
dc.date.issued2021-01
dc.descriptionVol. 16 Issue 1, Page (11-19)en_US
dc.description.abstractThis study aims to evaluate the optimum duration of flushing dental unit waterlines (DUWLs) in Universiti Sains Islam Malaysia (USIM) dental polyclinics for removal of heterotrophic bacteria. Water samples were obtained from triple air syringes at each dental chair from oral surgery clinic, outpatient clinic and polyclinic 17 at Faculty of Dentistry, USIM after 16 and 64 hours of not operating the dental units as baseline samples. This is followed by sampling after continuous flushing at 30 seconds, 1 minute, 2 minutes and 3 minutes of flushing duration. The levels of heterotrophic plate count (HPC) for each flushing duration were determined by quantification of colony forming units (CFUs) after cultivation of samples on plate count agar (PCA), R2A agar and 5% sheep blood agar (SBA). Statistically, there was no significant reduction in CFUs of HPC for all flushing duration compared to baseline (P>0.05) with the most notable HPC reducing level after 1 minute and 3 minutes of flushing DUWLs. However, HPC level at USIM dental clinics is still exceeding the recommendation by Centers for Disease Control and Prevention (CDC) which should be less than 500 CFU/mL. The existing method of controlling DUWLs contamination in USIM dental clinics is only by flushing DUWLs 1 minute every morning prior to dental treatment as recommended by Malaysian Dental Council (MDC) without the use of chemical germicides. Thus, the flushing method alone is not reliable to reduce the number of microorganisms in the DUWLs.en_US
dc.identifier.citationJohn Chong KH, Adnan SNA, Ismail NA (2021). The Optimum Duration of Flushing Dental Unit Waterlines for Microbial Removal. Arch Orofac Sci, 16(1): 11-19.en_US
dc.identifier.doi10.21315/aos2021.16.1.2
dc.identifier.doi11
dc.identifier.doi19
dc.identifier.issn1823-8602
dc.identifier.issue1
dc.identifier.urihttps://eds.s.ebscohost.com/eds/pdfviewer/pdfviewer?vid=1&sid=9a8755d2-c917-40dc-96f6-fc4ee7f5c4ad%40redis
dc.identifier.urihttps://oarep.usim.edu.my/handle/123456789/7539
dc.identifier.volume16
dc.language.isoen_USen_US
dc.publisherUSMen_US
dc.relation.ispartofArchives of Orofacial Sciencesen_US
dc.subjectBiofilms, dental unit waterlines, flushing duration, heterotrophic plate count.en_US
dc.titleThe Optimum Duration of Flushing Dental Unit Waterlines for Microbial Removalen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
The Optimum Duration of Flushing Dental Unit Waterlines for Mirobial Removal.pdf
Size:
350.5 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Plain Text
Description: