Publication:
Reliable Monitoring Of Oxygen Saturation Via Pulse Oximetry: Which Site To Choose?

dc.contributor.authorJuliana, Nen_US
dc.contributor.authorAzmani, Sen_US
dc.contributor.authorIdrose, Aen_US
dc.contributor.authorAmirfaiz, Sen_US
dc.contributor.authorRoslan, NAen_US
dc.contributor.authorSulaiman, AHen_US
dc.contributor.authorAmin, NAen_US
dc.contributor.authorFahmy, NIMen_US
dc.contributor.authorRahman, HAen_US
dc.date.accessioned2024-05-29T03:27:59Z
dc.date.available2024-05-29T03:27:59Z
dc.date.issued2017
dc.descriptionJ Fundam Appl Sci. 2017, 9(4S), 122-130en_US
dc.description.abstractThis study focuses on identifying the best site for placement of pulse oximeter probe for accurate measuring of oxygen saturation. Twenty-three healthy male volunteers aged 20 to 40 years old were recruited in this study. Cold pressor test was done to stimulate vasoactivity and 460 measurements of SpO(2) level were obtained throughout the study. The results were analyzed using ANOVA with p < 0.05 was considered to be significant. Bias between sites are determined using Bland-Altman plot whilst the internal consistency of each measurement sites are identified via Cronbach-Alpha (alpha). Results showed that the best site for cutaneous oxygen saturation measurement is at the earlobe using the ear sensor. Portable finger pulse oximeter oxygen saturation estimation is accurate and reliable at specific fingers (thumb, right middle and right ring fingers) regardless of stimulation on peripheral vasoactivity.en_US
dc.identifier.doi10.4314/jfas.v9i4s.54
dc.identifier.epage130
dc.identifier.issn1112-9867
dc.identifier.scopusWOS:000414750700008
dc.identifier.spage122
dc.identifier.urihttp://www.jfas.info
dc.identifier.urihttps://oarep.usim.edu.my/handle/123456789/12253
dc.identifier.volume9
dc.languageEnglish
dc.language.isoen_USen_US
dc.publisherUniv El Oued, Fac Science & Technologyen_US
dc.relation.ispartofJournal of Fundamental and Applied Sciencesen_US
dc.sourceWeb Of Science (ISI)
dc.subjectSpO(2)en_US
dc.subjectoxygen saturationen_US
dc.subjectcold pressor testen_US
dc.subjectvasoactivityen_US
dc.subjectpulse oxymetryen_US
dc.titleReliable Monitoring Of Oxygen Saturation Via Pulse Oximetry: Which Site To Choose?en_US
dc.typeArticleen_US
dspace.entity.typePublication

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Reliable Monitoring Of Oxygen Saturation Via Pulse Oximetry; Which Site To Choose'.pdf
Size:
243.48 KB
Format:
Adobe Portable Document Format