Publication: Comparative Analysis on Dielectric Gold and Aluminium Triangular Junctions: Impact of Ionic Strength and Background Electrolyte by pH Variations
dc.contributor.affiliations | Faculty of Engineering and Built Environment | |
dc.contributor.affiliations | Universiti Malaysia Perlis (UniMAP) | |
dc.contributor.affiliations | Central China Normal University | |
dc.contributor.affiliations | Universiti Sains Islam Malaysia (USIM) | |
dc.contributor.author | Letchumanan, Iswary | en_US |
dc.contributor.author | Arshad, M. K. Md | en_US |
dc.contributor.author | Gopinath, Subash C. B. | en_US |
dc.contributor.author | Rajapaksha, R. D. A. A. | en_US |
dc.contributor.author | Balakrishnan, S. R. | en_US |
dc.date.accessioned | 2024-05-29T03:26:27Z | |
dc.date.available | 2024-05-29T03:26:27Z | |
dc.date.issued | 2020 | |
dc.description.abstract | Field of generating a surface thin film is emerging broadly in sensing applications to obtain the quick and fast results by forming the high-performance sensors. Incorporation of thin film technologies in sensor development for the better sensing could be a promising way to attain the current requirements. This work predominantly delineates the fabrication of the dielectric sensor using two different sensing materials (Gold and Aluminium). Conventional photolithography was carried out using silicon as a base material and the photo mask of the dielectric sensor was designed by AutoCAD software. The physical characterization of the fabricated sensor was done by Scanning Electron Microscope, Atomic Force Microscope, High Power Microscope and 3D-nano profiler. The electrical characterization was performed using Keithley 6487 picoammeter with a linear sweep voltage of 0 to 2V at 0.01V step voltage. By pH scouting, I-V measurements on the bare sensor were carried out, whereby the gold electrodes conducts a least current than aluminium dielectrodes. Comparative analysis with pH scouting reveals that gold electrode is suitable under varied ionic strengths and background electrolytes, whereas aluminium electrodes were affected by the extreme acid (pH 1) and alkali (pH 12) solutions. | |
dc.identifier.ArtNo | 6783 | |
dc.identifier.doi | 10.1038/s41598-020-63831-w | |
dc.identifier.issn | 2045-2322 | |
dc.identifier.issue | 1 | |
dc.identifier.scopus | WOS:000560323100005 | |
dc.identifier.scopus | 2-s2.0-85083797119 | |
dc.identifier.uri | https://www.scopus.com/inward/record.uri?eid=2-s2.0-85083797119&doi=10.1038%2fs41598-020-63831-w&partnerID=40&md5=f36561978888475d1078a0e0b5548586 | |
dc.identifier.uri | https://oarep.usim.edu.my/handle/123456789/12115 | |
dc.identifier.volume | 10 | |
dc.language | English | |
dc.language.iso | en_US | en_US |
dc.publisher | Nature Publishing Group | en_US |
dc.relation.ispartof | Scientific Reports | |
dc.source | Scopus | |
dc.title | Comparative Analysis on Dielectric Gold and Aluminium Triangular Junctions: Impact of Ionic Strength and Background Electrolyte by pH Variations | en_US |
dc.type | Article | en_US |
dspace.entity.type | Publication |
Files
Original bundle
1 - 1 of 1
Loading...
- Name:
- Comparative Analysis on Dielectric Gold and Aluminium Triangular Junctions_ Impact of Ionic Strength and Background Electrolyte by pH Variations.pdf
- Size:
- 2.55 MB
- Format:
- Adobe Portable Document Format