Publication:
Daylight Efficiency And Energy Saving Lighting To Maximize Students’ ‘Hafazan’ Performance And Visual Comfort: A Case Research Of A Selected Religious School

dc.contributor.authorElina Mohd Husinien_US
dc.contributor.authorMohd Zin Kandaren_US
dc.contributor.authorFadli Arabien_US
dc.contributor.authorRaja Nur Syaheeza Raja Mohd Yaziten_US
dc.date.accessioned2024-05-30T06:52:36Z
dc.date.available2024-05-30T06:52:36Z
dc.date.issued2021-10-06
dc.descriptionPAPER PROCEEDINGS THE 7TH INTERNATIONAL CONFERENCE ON QURAN AS FOUNDATION OF CIVILIZATION (SWAT) 2021 “ISLAMIC AND NON-REVEALED KNOWLEDGE IN FACING THE GLOBAL CHALLENGES” 6th – 7th October 2021 / 29 – 30 Safar 1443H Faculty of Quranic and Sunnah Studies Universiti Sains Islam Malaysiaen_US
dc.description.abstractThe philosophy of Illumination and the scientific knowledge of light show the significant impact to energy efficiency and the development of performance in a building. It is important to improve the intensity of daylight in classrooms through introducing various innovative design of window in order to reduce the non- performance behavior of students. Current study shows the illuminance level within the recommended range of 300 lx to 500 lx or higher reduced the students’ Arabic handwriting speed based on word per minute. Further in the process of ‘hafazan’ as a memorization process, reading and writing task must consider sufficient window to-wall ratio, optimum daylight level and reduce the glare effect at the position of ‘hafazan’ setting at 300mm height crossed leg (‘rehal’) working plane and 900mm table working plane as a comparison. This research had conducted at Kolej Genius Insan, Universiti Sains Islam Malaysia, Nilai to identify the optimum illuminance level with window to-wall ratio of 30% and task performance at 300mm and 900mm working plane. Daylighting minimizes the artificial lighting with sensor or dimming strategies which can reduce by 19% during the passive daylight technique is applied. When the distribution of the daylight and illuminance level meet the uniformity at a lower working plane, the student’s performance is achieved within acceptable glare index. This optimum level of daylight performance range will benefit the designer to insert in the future of energy efficiency guideline and provide a sustainable building.en_US
dc.identifier.urihttps://oarep.usim.edu.my/handle/123456789/16862
dc.language.isoen_USen_US
dc.publisherUniversiti Sains Islam Malaysiaen_US
dc.relation.conferencePROCEEDINGS THE 7TH INTERNATIONAL CONFERENCE ON QURAN AS FOUNDATION OF CIVILIZATION (SWAT) 2021en_US
dc.subjectDaylighting, Glare index, “Hafazan’ setting, Illuminance level, Energy savingen_US
dc.titleDaylight Efficiency And Energy Saving Lighting To Maximize Students’ ‘Hafazan’ Performance And Visual Comfort: A Case Research Of A Selected Religious Schoolen_US
dc.typeArticleen_US
dspace.entity.typePublication

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
DAYLIGHT EFFICIENCY AND ENERGY SAVING LIGHTING TO MAXIMIZE STUDENTS’.pdf
Size:
807.2 KB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Plain Text
Description:

Collections