Repository logo
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Српски
  • Yкраї́нська
  • Log In
    New user? Click here to register.Have you forgotten your password?
Repository logo
    Communities & Collections
    Research Outputs
    Fundings & Projects
    People
    Statistics
  • English
  • Català
  • Čeština
  • Deutsch
  • Español
  • Français
  • Gàidhlig
  • Italiano
  • Latviešu
  • Magyar
  • Nederlands
  • Polski
  • Português
  • Português do Brasil
  • Srpski (lat)
  • Suomi
  • Svenska
  • Türkçe
  • Tiếng Việt
  • Қазақ
  • বাংলা
  • हिंदी
  • Ελληνικά
  • Српски
  • Yкраї́нська
  • Log In
    New user? Click here to register.Have you forgotten your password?
  1. Home
  2. Staff Publications
  3. Other Publications
  4. Hydrogen-natural Gas Mixture Leak Detection Using Reduced Order Modelling
 
  • Details
Options

Hydrogen-natural Gas Mixture Leak Detection Using Reduced Order Modelling

Journal
Applied and Computational Mathematics
Date Issued
2015
Author(s)
Norazlina Subani
Norsarahaida Amin
Baba Galadima Agaie
DOI
10.11648/j.acm.20150403.16
Abstract
Transient pressure wave detection analysis to detect the location of leakage on a pipeline containing hydrogen-natural gas mixture is presented. The transient pressure wave is generated either by rapid or sudden closure of the downstream shut-off valve. The governing equations of unsteady, compressible and isothermal one-dimensional flow are solved using the reduced order modelling technique. The solutions obtained when the transient condition is generated using the rapid closure valve show good agreement with published results. When the sudden closure valve is considered, the transient pressure, celerity wave, mass flux and the amount of leak discharge are shown to increase when the hydrogen mass ratio is increased. The amount of leak discharge which is calculated based on the computed celerity and pressure waves is found to be dependent on the leak positions.
Subjects

Leak Detection, Press...

File(s)
Loading...
Thumbnail Image
Name

Hydrogen-Natural Gas Mixture Leak Detection Using Reduced Order Modelling.pdf

Size

400.39 KB

Format

Adobe PDF

Checksum

(MD5):d14501c0ab2c9fee72b16a1d120c488f

Welcome to SRP

"A platform where you can access full-text research
papers, journal articles, conference papers, book
chapters, and theses by USIM researchers and students.”

Contact:
  • ddms@usim.edu.my
  • 06-798 6206 / 6221
  • USIM Library
Follow Us:
READ MORE Copyright © 2024 Universiti Sains Islam Malaysia