Publication:
Analysis on the Effect of Sensor Views in Image Reconstruction Produced by Optical Tomography System Using Charge-Coupled Device

dc.contributor.affiliationsFaculty of Engineering and Built Environment
dc.contributor.affiliationsUniversiti Sains Islam Malaysia (USIM)
dc.contributor.affiliationsUniversiti Tun Hussein Onn Malaysia (UTHM)
dc.contributor.affiliationsUniversiti Teknologi Malaysia (UTM)
dc.contributor.affiliationsUniversiti Malaysia Perlis (UniMAP)
dc.contributor.affiliationsJemmy Mohd Rohani Enterprise
dc.contributor.authorJamaludin J.en_US
dc.contributor.authorRahim R.A.en_US
dc.contributor.authorFazul Rahiman M.H.en_US
dc.contributor.authorMohd Rohani J.en_US
dc.date.accessioned2024-05-28T08:33:21Z
dc.date.available2024-05-28T08:33:21Z
dc.date.issued2018
dc.descriptionVolume: 27 Issue: 4en_US
dc.description.abstractOptical tomography (OPT) is a method to capture a cross-sectional image based on the data obtained by sensors, distributed around the periphery of the analyzed system. This system is based on the measurement of the final light attenuation or absorption of radiation after crossing the measured objects. The number of sensor views will affect the results of image reconstruction, where the high number of sensor views per projection will give a high image quality. This research presents an application of charge-coupled device linear sensor and laser diode in an OPT system. Experiments in detecting solid and transparent objects in crystal clear water were conducted. Two numbers of sensors views, 160 and 320 views are evaluated in this research in reconstructing the images. The image reconstruction algorithms used were filtered images of linear back projection algorithms. Analysis on comparing the simulation and experiments image results shows that, with 320 image views giving less area error than 160 views. This suggests that high image view resulted in the high resolution of image reconstruction. � 1992-2012 IEEE.en_US
dc.description.natureFinalen_US
dc.identifier.ArtNo8207602
dc.identifier.CODENIIPRE
dc.identifier.citationJ. Jamaludin, R. A. Rahim, M. H. Fazul Rahiman and J. Mohd Rohani, "Analysis on the Effect of Sensor Views in Image Reconstruction Produced by Optical Tomography System Using Charge-Coupled Device," in IEEE Transactions on Image Processing, vol. 27, no. 4, pp. 1689-1696, April 2018, doi: 10.1109/TIP.2017.2783620.en_US
dc.identifier.doi10.1109/TIP.2017.2783620
dc.identifier.epage1696
dc.identifier.issn10577149
dc.identifier.issue4
dc.identifier.scopus2-s2.0-85039785516
dc.identifier.spage1689
dc.identifier.urihttps://www.scopus.com/inward/record.uri?eid=2-s2.0-85039785516&doi=10.1109%2fTIP.2017.2783620&partnerID=40&md5=cac54e93ed8eed4b18323973891c3c93
dc.identifier.urihttps://ieeexplore.ieee.org/document/8207602/citations#citations
dc.identifier.urihttps://oarep.usim.edu.my/handle/123456789/9055
dc.identifier.volume27
dc.languageEnglish
dc.language.isoen_USen_US
dc.publisherInstitute of Electrical and Electronics Engineers Inc.en_US
dc.relation.ispartofIEEE Transactions on Image Processingen_US
dc.sourceScopus
dc.subjectarea erroren_US
dc.subjectcharge-coupled deviceen_US
dc.subjectimage reconstructionen_US
dc.subjectOptical tomography systemen_US
dc.subjectsensor viewsen_US
dc.subjectCharge coupled devicesen_US
dc.subjectImage analysisen_US
dc.subjectImage processingen_US
dc.subjectObject detectionen_US
dc.subjectOptical tomographyen_US
dc.subjectCross sectional imageen_US
dc.subjectFiltered imagesen_US
dc.subjectHigh image qualityen_US
dc.subjectHigh resolutionen_US
dc.subjectImage reconstruction algorithmen_US
dc.subjectLight attenuationen_US
dc.subjectLinear back projection algorithmsen_US
dc.subjectTransparent objectsen_US
dc.subjectImage reconstructionen_US
dc.titleAnalysis on the Effect of Sensor Views in Image Reconstruction Produced by Optical Tomography System Using Charge-Coupled Deviceen_US