Publication:
Analysis On The Performance Of Led And Laser Diode With Charge Coupled Device (CCD) Linear Sensor Measuring Diameter Of Object

dc.contributor.authorJamaludin J.en_US
dc.contributor.authorRahim, RAen_US
dc.contributor.authorRahim, HAen_US
dc.contributor.authorRahiman, HFen_US
dc.contributor.authorMuji, SZMen_US
dc.contributor.authorJumaah, MFen_US
dc.contributor.authorFadzil, NSMen_US
dc.contributor.authorAhmad, Nen_US
dc.contributor.authorSahlan, Sen_US
dc.contributor.authorAhmad, Aen_US
dc.contributor.authorYunus, Yen_US
dc.contributor.authorAbas, KHen_US
dc.date.accessioned2024-05-29T02:51:13Z
dc.date.available2024-05-29T02:51:13Z
dc.date.issued2015
dc.descriptionVol. 77 No. 17: Special Issue on Sensor Technology and Control System Applications Vol. 3en_US
dc.description.abstractSimple experiment measuring diameter of a solid object (coin) using LED and laser diode with Charge Coupled Device (CCD) linear sensor was conducted in this early stage study. Mostly, CCD and laser diode system are higher in cost because CCD used in industries equipped with an anti blooming protection system to protect the CCD pixel from receiving too high laser light intensities. Low cost atomic laser (Helium: Neon 10: 1) with simple modification on light propagation is introduced. Combination of fan beam and parallel beam projection helps to reduce light intensities and expand laser light coverage area. Statistical analyses based on dot plot graph, Anderson Darling test and T-test were applied to choose the best transmitter for Charge Coupled Device (CCD) sensor. Based on T-test results with 95% confidence interval, low intensity laser diode for 5 and 10 cent diameter measurement gave P-value greater than 0.05, accepts laser as the best transmitter compared to LED. Single sensor data for LED and laser used for image reconstruction as an additional approach to prove the above result.en_US
dc.identifier.citationJamaludin, J., Abdul Rahim, R., Abdul Rahim, H., Rahiman, H. F., Mohd Muji, S. Z., Jumaah, M. F., Mohd Fadzil, N. S., Ahmad, N., Sahlan, S., Ahmad, A., Yunus, Y., & Abas, K. H. (2015). ANALYSIS ON THE PERFORMANCE OF LED AND LASER DIODE WITH CHARGE COUPLED DEVICE (CCD) LINEAR SENSOR MEASURING DIAMETER OF OBJECT. Jurnal Teknologi, 77(17). https://doi.org/10.11113/jt.v77.6418en_US
dc.identifier.doi10.11113/jt.v77.6418
dc.identifier.epage25
dc.identifier.issn0127-9696
dc.identifier.issue17
dc.identifier.scopusWOS:000218625700003
dc.identifier.spage19
dc.identifier.urihttps://journals.utm.my/jurnalteknologi/article/view/6418
dc.identifier.urihttps://oarep.usim.edu.my/handle/123456789/11167
dc.identifier.volume77
dc.languageEnglish
dc.language.isoen_USen_US
dc.publisherPenerbit UTM Pressen_US
dc.relation.ispartofJurnal Teknologien_US
dc.sourceWeb Of Science (ISI)
dc.subjectCharge Coupled Device (CCD)en_US
dc.subjectlaser diodeen_US
dc.subjectLight Emitting Diode (LED)en_US
dc.subjectmeasurementen_US
dc.titleAnalysis On The Performance Of Led And Laser Diode With Charge Coupled Device (CCD) Linear Sensor Measuring Diameter Of Objecten_US
dc.typeArticleen_US
dspace.entity.typePublication

Files

Original bundle
Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Analysis On The Performance Of Led And Laser Diode With Charge Coupled Device (CCD) Linear Sensor Measuring Diameter Of Object.pdf
Size:
732.85 KB
Format:
Adobe Portable Document Format