Publication:
Ruby Stone Clarity Inspection System Using Charge-Coupled Device (CCD) Linear Sensor

dc.contributorJuliza Jamaludin [Supervisor]
dc.contributor.authorFatinah binti Mohd Rahalimen_US
dc.date.accessioned2024-05-29T04:21:54Z
dc.date.available2024-05-29T04:21:54Z
dc.date.issued2023-03
dc.descriptionMatric: 3201435(FKAB)en_US
dc.description.abstractRubies are the most sought-after gems owing to their brilliance, hardness, and high-value. They require a complicated technique for determining their originality due to the lack of quantitative analysis. One of the important criteria in analyzing the rubies is the clarity. This research aims to develop an inspection system using a CCD (Charge-Coupled Device) linear sensor for determining the clarity of ruby stones. A CCD linear sensor system is developed to inspect the clarity of rubies. Several experiments are conducted using the CCD linear system to validate the capability of the CCD linear sensor in inspecting the clarity of rubies. The mean CCD voltage output in the laser ON condition when synthetic ruby is in the system shows a higher value compared to when there is no ruby in the system with 1.7918 V and 1.5835 V respectively. When natural ruby is placed in the CCD linear system in the laser ON condition, the CCD voltage output is 1.9771 V. The CCD voltage output data is validated using the statistical analysis and the reverse mathematical modelling. The reverse mathematical modelling proves that the CCD linear sensor system is an effective and reliable system in inspecting the clarity of rubies. The result shows almost similar refractive index values of natural and synthetic rubies to their actual refractive index with 98.87% and 94.33% accuracy respectively. Overall, it can be concluded that this CCD linear system provides a quantitative, accurate and reliable technique with average accuracy of 96.90%.en_US
dc.identifier.citationFatinah Mohd Rahalim. (2023). Ruby Stone Clarity Inspection System Using Charge-Coupled Device (CCD) Linear Sensor [Master’s thesis, Universiti Sains Islam Malaysia]. USIM Research Repository.en_US
dc.identifier.urihttps://oarep.usim.edu.my/handle/123456789/12579
dc.language.isoen_USen_US
dc.publisherUniversiti Sains Islam Malaysiaen_US
dc.subjectRubiesen_US
dc.subjectJewelryen_US
dc.subjectCCD (Charge-Coupled Device) linear sensoren_US
dc.subjectLinear sensoren_US
dc.titleRuby Stone Clarity Inspection System Using Charge-Coupled Device (CCD) Linear Sensoren_US
dc.typeThesisen_US
dspace.entity.typePublication

Files

Original bundle
Now showing 1 - 5 of 9
No Thumbnail Available
Name:
3201435 Declaration..pdf
Size:
5.33 MB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
3201435 Introduction.pdf
Size:
1.07 MB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
3201435 Chapter 1.pdf
Size:
409.84 KB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
3201435 Chapter 2.pdf
Size:
5.2 MB
Format:
Adobe Portable Document Format
Loading...
Thumbnail Image
Name:
3201435 Chapter 3.pdf
Size:
2.79 MB
Format:
Adobe Portable Document Format
License bundle
Now showing 1 - 1 of 1
No Thumbnail Available
Name:
license.txt
Size:
1.71 KB
Format:
Plain Text
Description:

Collections